Braeburn 2020 Thermostat Operation Manual
The Braeburn 2020 is a programmable thermostat designed for single-stage heat/cool conventional and heat pump systems, including 250–750 millivolt heat-only systems. It features a large display, 7-day, 5-2 day, or non-programmable options, and precise temperature control, ideal for residential applications. Below are the key specifications and operation instructions.
Key Specifications
- Type: Programmable thermostat with 7-day, 5-2 day, or non-programmable options
- Compatibility:
- Single-stage heat/cool conventional and heat pump systems
- 250–750 millivolt heat-only systems
- Not compatible with multi-stage cooling beyond specifications or systems exceeding 30 VAC
- Power Source:
- Battery: Two "AA" alkaline batteries (included)
- Hardwired: 18-30 VAC with common (C) wire
- Electrical Rating:
- Terminal Load: 1 amp maximum per terminal
- Setpoint Range: 45°F to 90°F (7°C to 32°C)
- Accuracy: +/- 1°F (+/- 0.5°C)
- Display: Large LCD display with program indicators
- Operating Conditions:
- Ambient: 32°F to 105°F (0°C to 41°C)
- Humidity: 90% non-condensing max
- Dimensions: 3.70” H x 5.16” W x 1.38” D
- Features:
- Large easy-to-read display
- Adaptive Recovery Mode (ARM)
- Service Filter Monitor
- HOLD mode for temperature override
- Thermostat Configuration Options:
- Conventional or Heat Pump systems
- Fahrenheit or Celsius display
- Gas or Electric heat
Operation Instructions
Initial Setup
1. Insert Batteries: Install two "AA" alkaline batteries, ensuring correct polarity.
2. Power On: If hardwired, connect 24 VAC to the C terminal. The display should show the current time and temperature.
3. Configure System:
- Set installer switches on the back: CONV/HP for system type, F/C for temperature units, HG/HE for gas/electric heat.
- Press RESET after changes.
- Set time and day: Press DAY/TIME, use UP/DOWN arrows to adjust, press RETURN to save.
Operating the Thermostat
1. Select Mode: Use SYSTEM switch to choose HEAT, COOL, or OFF.
2. Adjust Temperature: Press UP/DOWN arrows to set desired temperature.
3. Programming: Press PROG to enter programming mode. Set schedules for 5-2 day (weekdays/weekends) with four events: MORN, DAY, EVE, NIGHT. Use defaults or customize temperatures and times.
4. HOLD Mode: Press HOLD to override program; select indefinite or 24-hour hold.
5. Verify Operation: In HEAT, set above room temp; "HEAT ON" displays. In COOL, set below; "COOL ON" displays.
Note: Adaptive Recovery starts heating/cooling early to reach setpoint on time.
Temperature Display Adjustment
The thermostat has +/-1°F accuracy, but no specific calibration menu is mentioned. Use a separate thermometer to verify. Relocate if near drafts or heat sources.
Troubleshooting
- No Display: Check battery polarity or replace batteries. Verify 24V power if hardwired. Press RESET.
- No Heat/Cool: Ensure SYSTEM mode is correct, setpoint is appropriate, power is on. Check wiring and circuit breakers. For heat pumps, verify EMER mode if applicable.
- Fan Runs Constantly: Set FAN to AUTO, not ON.
- Inaccurate Temperature: Ensure proper location away from drafts/heat sources.
- Erratic Operation: Reset thermostat. Check for voltage issues.
- Service Filter: Flashes when filter needs service; reset by pressing RETURN after changing filter.
- Buttons Not Working: Replace batteries and reset.
Installation Instructions
Warning: Turn off power before installation. For experienced technicians only. Conform to local codes.
Remove Old Thermostat
- Turn off power. Remove old thermostat, label wires for terminals. Handle mercury thermostats carefully and dispose properly.
Installing New Thermostat
- Separate thermostat from sub-base.
- Mount sub-base on wall, mark and drill holes, use anchors if needed.
- Connect wires to terminals per system type (e.g., Rh for heat power, W1 for heat relay).
- Set installer switches (CONV/HP, F/C, HG/HE).
- Push excess wire back, plug hole with insulation to prevent drafts.
- Snap thermostat onto sub-base.
Battery Location
- Batteries included; compartment on back. Replace when low battery indicator shows. Use alkaline "AA" batteries.
- If unoccupied for long periods, replace batteries before leaving.
Power Options
Use 24V AC for primary power with batteries as backup, or batteries only.
Thermostat Power Method | Description |
Battery Powered | Runs on two "AA" batteries. |
Hardwired with Battery Backup | Runs on 24V AC from transformer with batteries as backup. |
Caution: Ensure correct polarity for batteries. Do not short terminals during testing.