Braeburn 140202 2-Zone Controller Operation Manual

The Braeburn 140202 is a premier 2-zone controller designed for conventional heating/cooling systems and single or multi-stage heat pump systems. It features LED indicators for operation status, automatic equipment staging, and a 90-second purge cycle, ideal for residential zoning applications. Below are the key specifications and operation instructions.

1. Key Specifications 2. Operation Instructions 2.1. Initial Setup 2.2. Operating the Controller 2.3. Temperature Display Adjustment 2.4. Troubleshooting 3. Installation Instructions 3.1. Remove Old Controller 3.2. Installing New Controller 3.3. Battery Location 3.4. Power Options

Key Specifications

Operation Instructions

Initial Setup

1. Turn Off Power: Turn off power to the heating/air conditioning system.
2. Mount Panel: Mount near HVAC equipment, level for appearance. Use base as template, drill holes 4.5” apart, attach with screws/anchors.
3. Configure System:

Operating the Controller

1. Status LEDs: Heartbeat flashes once/second; RH/RC lit if powered; 24V Power lit; Damper green (open)/red (closed).
2. Zone Operation: No calls: all dampers open. Calls: corresponding dampers open, others close.
3. Purge Cycle: 90 seconds at end of call; no new calls answered.
4. Staging: Automatic based on time.
5. Emergency Heat: Switch to ON for heat pumps; cooling calls ignored.
Note: Use with compatible thermostats and dampers.

Temperature Display Adjustment

Not applicable; this is a zone controller without temperature display. Temperature control via connected thermostats.

Troubleshooting

Installation Instructions

Warning: Turn off power before installation. For experienced technicians only. Use only with described systems; conform to local codes.

Remove Old Controller

Installing New Controller

  1. Mount base near HVAC, level, drill holes, secure.
  2. Wire panel: Connect thermostats (Y, G, W/O/B, R, C per zone), HVAC equipment, dampers, transformer.
  3. Configure jumpers/DIP switches.
  4. Push excess wire back.
  5. Apply power, test system.

Battery Location

Power Options

Hardwired with dedicated 24 VAC transformer.

Controller Power MethodDescription
HardwiredRuns on 24 VAC from zoning transformer.

Caution: Size transformer for dampers. Use slave relay if over 35 VA. Do not short terminals.